Training Overview
We provide training programs for the following product lines:
Tridium Niagara 4 (Workplace N4) – Honeywell
EcoStruxure Building Operation (formerly StruxureWare™) or EBO Training
DDC Controller | Honeywell, Distech Canda, Johnson Controls,Easy IO – DDC Controller. |
---|---|
Network Controller | JACE 8000 – VYKON Network Controller, Jace 600 |
BMS software Platform | Niagara AX (Tridium Platform From HONEYWELL), Niagara 4 |
Protocol Com | Bacnet, Lon Works, Ethernet, TCP IP, Modbus. |
Sensors Interfacing | Temperature, DPS, Static Pressure Sensor, Schneider Electric – Energy Meters / Power Meters & its Integration with BMS |
VFD | Parameterisation and Wiring, programming, Integration with BMS |
BACnet IP / MSTP, 7. Modbus (RTU, TCP/IP) – Communication Protocol | Damper Actuator Integration, Integration with BMS |
Syllabus - In Detail
Description
A Global Training leader in Building Automation System, Energy management solutions, Technologics provides unique Training and services that optimize energy efficiency and comfort in buildings, all the while reducing operating costs.Building System and Controls training offers a comprehensive portfolio of technical courses to help you effectively monitor and coordinate your HVAC equipment and systems.
Courses are designed by professional instructors in partnership with industry experts, product engineers, technical support engineers, and product development teams. Using proven best practices gained through decades of building controls experience, we provide practical, results-oriented training tailored to your job.
Overview Of BMS
The objective of Building Management Systems (BMS system) is to manage & control the sub-systems within a building to ensure a pleasant, controlled and safe environment. A BMS can control some of the following building equipment’s or operation like: HVAC, CCTV, Access Control, Fire and Intruder Alarms, Lighting and even Power Consumption.
- Introduction to BMS and its sub-systems ( Eg: HVAC Controls, FCU, Package Unit, Roof Top Unit, Fire alarm system, Fire Fighting System ( Pumps ), smoke management system,CCTV , Access control systems, Lighting control systems, Public addressing systems, Car parking management system, Car parking Ventilation system, Audio/vedio system Integration, Chiller System, Cooling Tower etc.)
- Project Engineering – IO summary, cost sheet & estimation
- P & ID System drawings, Riser diagrams, Single Line Diagram ( SLD )
- Heating ventillation Air Conditioning ( HVAC Controls, Fan Coil Unit ( FCU ), Package Unit, Roof Top Unit, Heat Recovery Wheel Etc. Controls & design
- Relay & MCC Panel design and wiring- Star Delta & DOL Starter Panel
- Sensor Connection with DDC practical’s
- Sensor – Co2 Monitoring (0 to 10V or 4 to 20mA ) of Johnsen controls
- Sensor – Temp & Humidity (0 to 10V or 4 to 20mA )
- Sensor – thermocouple (temp), RTD
- Sensor – NPN & PNP type proximity
- Sensor – Differential pressure switch
- Sensor – Pressure transmitter (4 to 20 mA)
- Field Devices, Valve sizing calculations – Intrumentation selection & sizing
- VFD Programming, Testing & Commissioning
- Stand-alone DDC programming testing & commissioningrogramming in DDC ( Direct Digital controls )
- Uploading and downloading program
- DDC Panel wiring.
- Configuring the Network controller with DDC Controller & BMS Software
- Fetching and discovering the DDC’s and its Inputs & Outputs ( I/O’s ) in BMS software
- BMS Graphics design
- IBMS O&M manual & Training manual preparation